Other Related Products
-
1. Used for softening or demineralization water treatment systems, suitable for:a. Residential filter systemb. Boiler filter water system2. Control valves install to Water filter is used in food and beverage industry.3. Electronic power industry, metallurgy industry, pharmaceutical industry, chemical industry. -

JY DR Large Series Floated Bed Soften Valve
DR20\40\50\20T\40T Soften valve series is floating bed, all appearance and geometric parameters and parts is the same as the corresponding GR20\40\50\20T\40T, floating bed has a good water quality, to adapt high hardness of the raw water, configuration swap tank should be fine and high, runing velocity in the 30-60 m/h, but resin filling rate must be above 90%, being stable working pressure,The floating bed is not suitable for frequent starting and changing water consumption.
-

FLECK Control Valve 2850
Time-tested hydraulically balanced piston, seal and spacer design to pilot service flow and regeneration
Solid, lead-free brass valve body for superior strength and durability
Backwash capacity handles tanks up to 30″ diameter
1-1/2″ top mount control valve ideal for smaller size commercial/industrial applications
Consistent brining regardless of salt levels with timed brine refills
Choice of 7 or 12 day clock, manual or meter
Continuous flow rate of 51 GPM with a backwash of 49 GPM -

ROS-2210 Reverse Osmosis Program Controller
Single stage RO controller used for conductivity monitoring and process program control .
-

JY GL-1 Filter Control Valve
Meter and time dual mode, the meter mode, its inflow meter achieved all station can be set according to the water volume demanded , as long as set by the swap of tank volume (L) backwash water and wash water, set cycle running water volume(ton), according to the set value for each station after descending to the switch when the “0”, discontinued or no water stop decreasing and maintain. This series of products have beautiful appearance, high material precision of valve body parts, good strength and high temperature resistance, and the main valve body is connected with metal inserts with good maintainability.
-

FCT-8350 Flow Transmitter
Widely used for online measurement of acid&alkali in low concentrations and the low viscosity single-phase fluid of non-trade settlement process.
-


JY DR-1 Fixed Bed Up Flow Regenerate Softener Valve
Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.
-

JY ZR Double Tank Floating Bed Water Softener Valve
ZR type double tank floating bed control valve including ZR4-1/ZR4-1S(Side Loading), ZR10-1/ZR10-1S(Side Loading). It is equiped the inlet flow Meter and drainage flow meter, All the parameters is set by water volume, The double swap tank is for Alternating regeneration. Continuous water production, Water quality is stable , Adapted to the to high hardness water softening, such as the steam boiler and heating engineering and production process water.
-

DOP-6121 membrane DO Dissolved oxygen
Typical applications • Widely used in thermal boiler deaerator water and large and medium-sized industrial boiler feed water; • Operational supervision of reactor Primary circuit, secondary circuit circuits and condensate system; • On-line analysis of dissolved oxygen in circulating water of heat exchange system; • Deaeration control of marine fresh water system, thermal system and…