ROC-7000 Reverse Osmosis Ultra filtration controller
Applicable to all kinds of small and medium-sized single-stage, double-stage reverse osmosis control system. With simple operation, complete measurement and configuration, highly integrated system

Applicable to all kinds of small and medium-sized single-stage, double-stage reverse osmosis control system. With simple operation, complete measurement and configuration, highly integrated system

Versatile top or side mount is suitable for commercial or industrial applications
Backwash capacity accommodates tanks up to 63″ diameter
Flexible 7 or 12 day time clock or meter initiated regeneration
Ideal for most filter applications up to 42″

ROC-8221 is a combined control instrument of a single-stage reverse osmosis controller and double-channel on-line conductivity instrument.


Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

GR20\40\50\20T\40T series up flow regeneration fixed bed large valve series, water production range is 15T/ h-70t /h, the inlet flow meter is used to set the cycle of water production, slow backwash water and wash water, and the brine flow meter and the brine electric valve are used to specifically measure brine absorption and salt tank water supply.In the flow mode, the internal flow transducer realizes the switch of all stations as long as the amount of brine,the amount of slow washing water and the amount of washing water is set according to the volume (liter) of the swap tank. After the period of softening water amount (ton) is set according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

Multiplex display, display window with free configuration of 2/4 parameters;
Support bus data acquisition of 1-4 channels with arbitrary attributes;
Support 1 way two-wire system 4-20mA variable input;
Support WiFi and LORA and other wireless data acquisition;
The 3-way control output can be configured with the over-limit alarm or DI associated output of any measurement channel.
Fully sealed, wall-mounted shell, according with site protective capability of IP65 protection type.
With CE certification

Salt and water savings by using 100% capacity of the tank in service before switching to the second tank
Regenerates immediately when needed for continuous soft water
Corrosion-free fiber-reinforced polymer valve body

Fully adjustable, 5-cycle control delivers upflow backwash, downflow brining, slow rinse, rapid rinse, brine refill, and downflow service
Time-tested, hydraulically-balanced piston, seal and spacer, controls service flow and regeneration
Non-corrosive, fiber-reinforced polymer construction
Excellent flow rates (19 GPM continuous, 24 GPM peak)
Backwash capacity handles tanks up to 16″ diameter for softener, andĀ filter

Widely used for chemical industry,pharmaceutical,food,beverage,industrial coating,municipal water,Environmental,etc.conductivity (resisitivity) online measuring and control. It is a small-scale, industry leading and High Cost-Effective conductivity/resistivity integration online controller.