Other Related Products

  • JY GR-2 Economical Up Flow Regenerate Softening Valve

    Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

  • ROS-2210 Reverse Osmosis Program Controller

    Single stage RO controller used for conductivity monitoring and process program control .

  • EC-1800 Online Conductivity Meter

    High Cost-Effective ,widely used for chemical industry,paper making industry,industrial coating,pharmaceutical,food,beverage,municipal water,Environmental and so on.

  • JY GL-1 Filter Control Valve

    Meter and time dual mode, the meter mode, its inflow meter achieved all station can be set according to the water volume demanded , as long as set by the swap of tank volume (L) backwash water and wash water, set cycle running water volume(ton), according to the set value for each station after descending to the switch when the “0”, discontinued or no water stop decreasing and maintain. This series of products have beautiful appearance, high material precision of valve body parts, good strength and high temperature resistance, and the main valve body is connected with metal inserts with good maintainability.

  • Dissolved oxygen

    DOP-6121 membrane DO Dissolved oxygen

    Typical applications • Widely used in thermal boiler deaerator water and large and medium-sized industrial boiler feed water; • Operational supervision of reactor Primary circuit, secondary circuit circuits and condensate systemï¼› • On-line analysis of dissolved oxygen in circulating water of heat exchange system; • Deaeration control of marine fresh water system, thermal system and…

  • JY ZR Double Tank Floating Bed Water Softener Valve

    ZR type double tank floating bed control valve including ZR4-1/ZR4-1S(Side Loading), ZR10-1/ZR10-1S(Side Loading). It is equiped the inlet flow Meter and drainage flow meter, All the parameters is set by water volume, The double swap tank is for Alternating regeneration. Continuous water production, Water quality is stable , Adapted to the to high hardness water softening, such as the steam boiler and heating engineering and production process water.

  • ROC MFC-1202/ MFC-1382 General/Multi-parameter Online Controller

    Multiplex display, display window with free configuration of 2/4 parameters;
    Support bus data acquisition of 1-4 channels with arbitrary attributes;
    Support 1 way two-wire system 4-20mA variable input;
    Support WiFi and LORA and other wireless data acquisition;
    The 3-way control output can be configured with the over-limit alarm or DI associated output of any measurement channel.
    Fully sealed, wall-mounted shell, according with site protective capability of IP65 protection type.
    With CE certification

  • JY GR-1 Fixed Bed Softening Valve

    Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

  • ROC-7000 Reverse Osmosis Ultra filtration controller

    Applicable to all kinds of small and medium-sized single-stage, double-stage reverse osmosis control system. With simple operation, complete measurement and configuration, highly integrated system