ROS-8600 Distributed RO Program Control HMI Platform
Single stage RO controller used for conductivity monitoring and process program control .


Single stage RO controller used for conductivity monitoring and process program control .


Salt and water savings by using 100% capacity of the tank in service before switching to the second tank
Regenerates immediately when needed for continuous soft water
Corrosion-free fiber-reinforced polymer valve body


Turbidity is the expression of suspended objects in water to the degree of obstruction of light transmission. This product uses RS485 interface to communicate with the digital sensor, high data accuracy, strong anti-interference, can directly control the digital sensor calibration and automatic cleaning and other functions.


Free Chlorine (DPD) online automatic analyzer is mainly used for real-time monitoring of water plants, secondary water supply of pipe network, medical wastewater, kidney dialysis medical water, food and beverage water, swimming pools, circulating cooling water, enterprise discharge wastewater and other occasions.


GR20\40\50\20T\40T series up flow regeneration fixed bed large valve series, water production range is 15T/ h-70t /h, the inlet flow meter is used to set the cycle of water production, slow backwash water and wash water, and the brine flow meter and the brine electric valve are used to specifically measure brine absorption and salt tank water supply.In the flow mode, the internal flow transducer realizes the switch of all stations as long as the amount of brine,the amount of slow washing water and the amount of washing water is set according to the volume (liter) of the swap tank. After the period of softening water amount (ton) is set according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.


Widely used for online measurement of acid&alkali in low concentrations and the low viscosity single-phase fluid of non-trade settlement process.


DR20\40\50\20T\40T Soften valve series is floating bed, all appearance and geometric parameters and parts is the same as the corresponding GR20\40\50\20T\40T, floating bed has a good water quality, to adapt high hardness of the raw water, configuration swap tank should be fine and high, runing velocity in the 30-60 m/h, but resin filling rate must be above 90%, being stable working pressure,The floating bed is not suitable for frequent starting and changing water consumption.


This series instruments are widely used for online pH/ORP monitoring in environment protection water treatment, pure water treatment, industrial process and so on.

![[CL-9500] Water Quality Test Residual Chlorine Controller1](https://www.chimaytech.net/wp-content/uploads/2023/11/CL-9500-Water-Quality-Test-Residual-Chlorine-Controller1-1-300x300.png)
CL-9500 residual chlorine controller is a new controller. This meter has a high degree of intelligence and flexibility. It can measure Residual chlorine value and temperature at the same time. It is widely used in urban sewage treatment plants, water supply and other industries and can continuously measure the Residual chlorine value of solution.