FCT-8350 Flow Transmitter
Widely used for online measurement of acid&alkali in low concentrations and the low viscosity single-phase fluid of non-trade settlement process.

Widely used for online measurement of acid&alkali in low concentrations and the low viscosity single-phase fluid of non-trade settlement process.

GR20\40\50\20T\40T series up flow regeneration fixed bed large valve series, water production range is 15T/ h-70t /h, the inlet flow meter is used to set the cycle of water production, slow backwash water and wash water, and the brine flow meter and the brine electric valve are used to specifically measure brine absorption and salt tank water supply.In the flow mode, the internal flow transducer realizes the switch of all stations as long as the amount of brine,the amount of slow washing water and the amount of washing water is set according to the volume (liter) of the swap tank. After the period of softening water amount (ton) is set according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

Applicable to all kinds of small and medium-sized single-stage, double-stage reverse osmosis control system. With simple operation, complete measurement and configuration, highly integrated system

On-line analysis and process control of the oil refining, metallurgy,chemical synthesis industry process;

Single stage RO controller used for conductivity monitoring and process program control .


Multiplex display, display window with free configuration of 2/4 parameters;
Support bus data acquisition of 1-4 channels with arbitrary attributes;
Support 1 way two-wire system 4-20mA variable input;
Support WiFi and LORA and other wireless data acquisition;
The 3-way control output can be configured with the over-limit alarm or DI associated output of any measurement channel.
Fully sealed, wall-mounted shell, according with site protective capability of IP65 protection type.
With CE certification

ZR type double tank floating bed control valve including ZR4-1/ZR4-1S(Side Loading), ZR10-1/ZR10-1S(Side Loading). It is equiped the inlet flow Meter and drainage flow meter, All the parameters is set by water volume, The double swap tank is for Alternating regeneration. Continuous water production, Water quality is stable , Adapted to the to high hardness water softening, such as the steam boiler and heating engineering and production process water.

Flexible 7 or 12 day time clock or meter initiated regeneration
Fully adjustable, 5-cycle control delivers upflow back wash, downflow brining, slow rinse, rapid rinse and down flow service
Designed for single tank or multi-tank systems, alternating or interlocking
Continuous flow rate of 250 GPM