FLECK Control Valve 5600
FLECK control valve 5600 softening water equipment generally uses fixed bed downstream
regeneration, the working process is operation, backwashing, regeneration, replacement,
positive washing, salt tank water injection.

FLECK control valve 5600 softening water equipment generally uses fixed bed downstream
regeneration, the working process is operation, backwashing, regeneration, replacement,
positive washing, salt tank water injection.

Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

1) Working Position : Service->Back Wash->Brine and slow Rinse->fast rinse->Refill softened water->service.
Downflow type .Working Position : Service->Back Wash->Brine and slow Rinse->fast rinse->Refill->service.
2) Using ceramic moving valve disk, small rotation torque.
3) Abrasion resistance of sealing surface, outstanding and long-lived deal.
4) It could be operated with pressure directly.



Turbidity is the expression of suspended objects in water to the degree of obstruction of light transmission. This product uses RS485 interface to communicate with the digital sensor, high data accuracy, strong anti-interference, can directly control the digital sensor calibration and automatic cleaning and other functions.

Single stage RO controller used for conductivity monitoring and process program control .

DR20\40\50\20T\40T Soften valve series is floating bed, all appearance and geometric parameters and parts is the same as the corresponding GR20\40\50\20T\40T, floating bed has a good water quality, to adapt high hardness of the raw water, configuration swap tank should be fine and high, runing velocity in the 30-60 m/h, but resin filling rate must be above 90%, being stable working pressure,The floating bed is not suitable for frequent starting and changing water consumption.

Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

On-line analysis and process control of the oil refining, metallurgy,chemical synthesis industry process;