FLECK Control Valve 5600
FLECK control valve 5600 softening water equipment generally uses fixed bed downstream
regeneration, the working process is operation, backwashing, regeneration, replacement,
positive washing, salt tank water injection.

FLECK control valve 5600 softening water equipment generally uses fixed bed downstream
regeneration, the working process is operation, backwashing, regeneration, replacement,
positive washing, salt tank water injection.

Multiplex display, display window with free configuration of 2/4 parameters;
Support bus data acquisition of 1-4 channels with arbitrary attributes;
Support 1 way two-wire system 4-20mA variable input;
Support WiFi and LORA and other wireless data acquisition;
The 3-way control output can be configured with the over-limit alarm or DI associated output of any measurement channel.
Fully sealed, wall-mounted shell, according with site protective capability of IP65 protection type.
With CE certification

One kind of popular and cost-effective online pH/ORP controller.

RF double tank floating bed plane multi-way valve, realized tow tank softening at the same time and regenerating alternate, integrated with brine jet device and brine flow meter and brine electric valve, with soft water flow meter, guarantees the water softening , the water regenerating and water filling to salt box, Complete according to the set volume.as long as the factory according to the raw water hardness set corresponding operation parameters, can always guarantee the stable operation of the equipment, guarantee the softened water and salt consumption.

1) Working Position : Service->Back Wash->Brine and slow Rinse->fast rinse->Refill softened water->service.
Downflow type .Working Position : Service->Back Wash->Brine and slow Rinse->fast rinse->Refill->service.
2) Using ceramic moving valve disk, small rotation torque.
3) Abrasion resistance of sealing surface, outstanding and long-lived deal.
4) It could be operated with pressure directly.


Single stage RO controller used for conductivity monitoring and process program control .


Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

CIT-8800 Inductive Conductivity / Concentration Online Controller is a new developed conductivity/Concentration/TDS/Temperature integration controller,with No electrode inductive Conductivity Sensor.