ROS-8600 Distributed RO Program Control HMI Platform
Single stage RO controller used for conductivity monitoring and process program control .

Single stage RO controller used for conductivity monitoring and process program control .

Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.




Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.


Turbidity is the expression of suspended objects in water to the degree of obstruction of light transmission. This product uses RS485 interface to communicate with the digital sensor, high data accuracy, strong anti-interference, can directly control the digital sensor calibration and automatic cleaning and other functions.


CL-9500 residual chlorine controller is a new controller. This meter has a high degree of intelligence and flexibility. It can measure Residual chlorine value and temperature at the same time. It is widely used in urban sewage treatment plants, water supply and other industries and can continuously measure the Residual chlorine value of solution.

Multiplex display, display window with free configuration of 2/4 parameters;
Support bus data acquisition of 1-4 channels with arbitrary attributes;
Support 1 way two-wire system 4-20mA variable input;
Support WiFi and LORA and other wireless data acquisition;
The 3-way control output can be configured with the over-limit alarm or DI associated output of any measurement channel.
Fully sealed, wall-mounted shell, according with site protective capability of IP65 protection type.
With CE certification


Fluorescence quenching principle, no need for internal filling, no oxygen consumption, and easy maintenance;
The service life of the fluorescent membrane cap is more than one year (under ideal conditions);
Original altitude, atmospheric oxygen partial pressure, temperature compensation, to improve the authenticity of the data;