FLECK Control Valve 9100
Salt and water savings by using 100% capacity of the tank in service before switching to the second tank
Regenerates immediately when needed for continuous soft water
Corrosion-free fiber-reinforced polymer valve body

Salt and water savings by using 100% capacity of the tank in service before switching to the second tank
Regenerates immediately when needed for continuous soft water
Corrosion-free fiber-reinforced polymer valve body


Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

GR20\40\50\20T\40T series up flow regeneration fixed bed large valve series, water production range is 15T/ h-70t /h, the inlet flow meter is used to set the cycle of water production, slow backwash water and wash water, and the brine flow meter and the brine electric valve are used to specifically measure brine absorption and salt tank water supply.In the flow mode, the internal flow transducer realizes the switch of all stations as long as the amount of brine,the amount of slow washing water and the amount of washing water is set according to the volume (liter) of the swap tank. After the period of softening water amount (ton) is set according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

Widely used for electric power,electronics,metallurgy,petrochemical,pharmaceutical ,food and beverage,environmental protection field.

Typical applications • Widely used in thermal boiler deaerator water and large and medium-sized industrial boiler feed water; • Operational supervision of reactor Primary circuit, secondary circuit circuits and condensate system; • On-line analysis of dissolved oxygen in circulating water of heat exchange system; • Deaeration control of marine fresh water system, thermal system and…

FL-9900 flow transmitter adopts all-digital circuit design, which has the characteristics of simple circuit structure, high precision, good reproducibility, strong anti-interference ability, high protection level, easy installation and use. Widely used in water treatment, cooling water, chemical, biopharmaceutical, power plants, cement plants, sewage treatment, colleges and universities, research institutes and other industrial processes real-time, on-line monitoring of fluids。

Time-tested hydraulically balanced piston, seal and spacer design to pilot service flow and regeneration
Solid, lead-free brass valve body for superior strength and durability
Backwash capacity handles tanks up to 30″ diameter
1-1/2″ top mount control valve ideal for smaller size commercial/industrial applications
Consistent brining regardless of salt levels with timed brine refills
Choice of 7 or 12 day clock, manual or meter
Continuous flow rate of 51 GPM with a backwash of 49 GPM

ROC-8221 is a combined control instrument of a single-stage reverse osmosis controller and double-channel on-line conductivity instrument.

Free Chlorine (DPD) online automatic analyzer is mainly used for real-time monitoring of water plants, secondary water supply of pipe network, medical wastewater, kidney dialysis medical water, food and beverage water, swimming pools, circulating cooling water, enterprise discharge wastewater and other occasions.