No products were found matching your selection.

Other Related Products

  • Placeholder

    JY RF Large Double Tank Water Softener Valve

    RF double tank floating bed plane multi-way valve, realized tow tank softening at the same time and regenerating alternate, integrated with brine jet device and brine flow meter and brine electric valve, with soft water flow meter, guarantees the water softening , the water regenerating and water filling to salt box, Complete according to the set volume.as long as the factory according to the raw water hardness set corresponding operation parameters, can always guarantee the stable operation of the equipment, guarantee the softened water and salt consumption.

  • Placeholder

    JY ZR Double Tank Floating Bed Water Softener Valve

    ZR type double tank floating bed control valve including ZR4-1/ZR4-1S(Side Loading), ZR10-1/ZR10-1S(Side Loading). It is equiped the inlet flow Meter and drainage flow meter, All the parameters is set by water volume, The double swap tank is for Alternating regeneration. Continuous water production, Water quality is stable , Adapted to the to high hardness water softening, such as the steam boiler and heating engineering and production process water.

  • Placeholder

    JY GR-2 Economical Up Flow Regenerate Softening Valve

    Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

  • Placeholder

    JY Brine Valve

    This series of brine valves have overcome the deficiency of the products existing in the market. It can not only protect water injection and check the air, but also can limit the extreme amount of water injection and filter the water running inside. If water injection is too fast, the liquid level inside the brine well will spill out quickly and the injection has to be shut down, which will result in the insufficiency of water inside the brine tank and have bad influence upon the outcome of recycling. This kind of brine valves depends on water pressure to work. It is reliable in working and valuable in extensive employment.

  • Placeholder

    JY GR-1 Fixed Bed Softening Valve

    Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

  • Placeholder

    FL-9900 High Precision Type Runner Flow Controller

    FL-9900 flow transmitter adopts all-digital circuit design, which has the characteristics of simple circuit structure, high precision, good reproducibility, strong anti-interference ability, high protection level, easy installation and use. Widely used in water treatment, cooling water, chemical, biopharmaceutical, power plants, cement plants, sewage treatment, colleges and universities, research institutes and other industrial processes real-time, on-line monitoring of fluids。

  • Placeholder

    JY GR Large Series Fixed Bed Softening Valve

    GR20\40\50\20T\40T series up flow regeneration fixed bed large valve series, water production range is 15T/ h-70t /h, the inlet flow meter is used to set the cycle of water production, slow backwash water and wash water, and the brine flow meter and the brine electric valve are used to specifically measure brine absorption and salt tank water supply.In the flow mode, the internal flow transducer realizes the switch of all stations as long as the amount of brine,the amount of slow washing water and the amount of washing water is set according to the volume (liter) of the swap tank. After the period of softening water amount (ton) is set according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.

  • Multi Parameter Online Water Quality Residual Chlorine AnalyzerMulti Parameter Online Water Quality Residual Chlorine Analyzer

    POP-8300 Free Chlorine online controller

    • On-line analysis of municipal water tank disinfection
    • Chlorine supplement control of pipe secondary pressurization (no negative pressure)
  • Placeholder

    MF Serials Manual Water Softener Valve

    1) Working Position : Service->Back Wash->Brine and slow Rinse->fast rinse->Refill softened water->service.
    Downflow type .Working Position : Service->Back Wash->Brine and slow Rinse->fast rinse->Refill->service.
    2) Using ceramic moving valve disk, small rotation torque.
    3) Abrasion resistance of sealing surface, outstanding and long-lived deal.
    4) It could be operated with pressure directly.