No products were found matching your selection.
Other Related Products
-

Meter and time dual mode, the meter mode, its inflow meter achieved all station can be set according to the water volume demanded , as long as set by the swap of tank volume (L) backwash water and wash water, set cycle running water volume(ton), according to the set value for each station after descending to the switch when the “0”, discontinued or no water stop decreasing and maintain. This series of products have beautiful appearance, high material precision of valve body parts, good strength and high temperature resistance, and the main valve body is connected with metal inserts with good maintainability.
-

Applicable to all kinds of small and medium-sized single-stage, double-stage reverse osmosis control system. With simple operation, complete measurement and configuration, highly integrated system
-

Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.
-

Incorporates 2 time-tested, hydraulically-balanced pistons to independently pilot service flow and regeneration
For use with single or multiple tank systems
Backwashes softener tanks up to 36″ diameter
Continuous flow rate of 106 GPM
-

GL-2 Series of economical control valve is the same as the corresponding GL-1 in function and principle. it use “One dynamic & two static” three layer ceramic valve core technology, It adopts four key controller operation setting method, needless rotation station identification when power on every time.The inlet and outlet water is set on the side of the valve body.Small size, simple structure, no wear and tear, permanent life.It can be widely used in the purification of industrial and civil.
-

FL-9900 flow transmitter adopts all-digital circuit design, which has the characteristics of simple circuit structure, high precision, good reproducibility, strong anti-interference ability, high protection level, easy installation and use. Widely used in water treatment, cooling water, chemical, biopharmaceutical, power plants, cement plants, sewage treatment, colleges and universities, research institutes and other industrial processes real-time, on-line monitoring of fluids。
-

Meter, time clock dual mode. In flow mode, the internal flow transmitter realizes the function of setting water volume as required. After setting regeneration water volume and cleaning water volume of exchange tank, the period of softening water amount (ton) according to the hardness of the raw water, each station decreases to “0” according to the set value, and stops decreasing and maintains when the water is out of service or no water.
-

Suitable for large residential/light commercial applications
Fully adjustable, 5-cycle control delivers controlled upflow backwash, downflow brining and slow rinse, rapid rinse, timed brine refill and downflow service
Backwash capacity handles tanks up to 24″ diameter
Mechanical control (7- or 12-day clock or metered initiated regeneration)
Valve body is solid, lead-free brass
Time tested, hydraulically-balanced piston, seal, and spacer concept to pilot service flow and regeneration
-


Measure range :TUR-6101 (0~5NTU) ;TUR-6102 (0~100NTU)