ROS-8600 Distributed RO Program Control HMI Platform
Single stage RO controller used for conductivity monitoring and process program control .

Single stage RO controller used for conductivity monitoring and process program control .

Multiplex display, display window with free configuration of 2/4 parameters;
Support bus data acquisition of 1-4 channels with arbitrary attributes;
Support 1 way two-wire system 4-20mA variable input;
Support WiFi and LORA and other wireless data acquisition;
The 3-way control output can be configured with the over-limit alarm or DI associated output of any measurement channel.
Fully sealed, wall-mounted shell, according with site protective capability of IP65 protection type.
With CE certification

On-line analysis and process control of the oil refining, metallurgy,chemical synthesis industry process;


Fluorescence quenching principle, no need for internal filling, no oxygen consumption, and easy maintenance;
The service life of the fluorescent membrane cap is more than one year (under ideal conditions);
Original altitude, atmospheric oxygen partial pressure, temperature compensation, to improve the authenticity of the data;

For complex industrial processes, sewage treatment, water reuse, environmental monitoring, industrial field control, chemical process, thermal detection and discrete control, data transmission control and remote data transmission.

Widely used for online measurement of acid&alkali in low concentrations and the low viscosity single-phase fluid of non-trade settlement process.

CL-9500 residual chlorine controller is a new controller. This meter has a high degree of intelligence and flexibility. It can measure Residual chlorine value and temperature at the same time. It is widely used in urban sewage treatment plants, water supply and other industries and can continuously measure the Residual chlorine value of solution.

ROC-8221 is a combined control instrument of a single-stage reverse osmosis controller and double-channel on-line conductivity instrument.

DR20\40\50\20T\40T Soften valve series is floating bed, all appearance and geometric parameters and parts is the same as the corresponding GR20\40\50\20T\40T, floating bed has a good water quality, to adapt high hardness of the raw water, configuration swap tank should be fine and high, runing velocity in the 30-60 m/h, but resin filling rate must be above 90%, being stable working pressure,The floating bed is not suitable for frequent starting and changing water consumption.