{"id":31412,"date":"2026-09-03T13:02:01","date_gmt":"2026-09-03T05:02:01","guid":{"rendered":"https:\/\/www.chimaytech.net\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/"},"modified":"2026-09-03T13:02:01","modified_gmt":"2026-09-03T05:02:01","slug":"the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch","status":"publish","type":"post","link":"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/","title":{"rendered":"The Rise of Short-Chain PFAS Monitoring: What Water Operators Need to Know from Shanghai ChiMay"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#The_Rise_of_Short-Chain_PFAS_Monitoring_What_Water_Operators_Need_to_Know_from_Shanghai_ChiMay\" >The Rise of Short-Chain PFAS Monitoring: What Water Operators Need to Know from Shanghai ChiMay<\/a><ul class='ez-toc-list-level-2' ><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#The_Short_Version\" >The Short Version<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#The_PFAS_Mix_Is_Changing_Under_Our_Feet\" >The PFAS Mix Is Changing Under Our Feet<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Understanding_Short-Chain_PFAS\" >Understanding Short-Chain PFAS<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#What_Defines_Short-Chain_PFAS\" >What Defines Short-Chain PFAS<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Regulatory_Attention_and_Uncertainty\" >Regulatory Attention and Uncertainty<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Detection_Challenges_for_Short-Chain_PFAS\" >Detection Challenges for Short-Chain PFAS<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Analytical_Limitations\" >Analytical Limitations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Surrogate_Monitoring_as_a_Solution\" >Surrogate Monitoring as a Solution<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Treatment_Implications\" >Treatment Implications<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#GAC_and_Ion-Exchange_Challenges\" >GAC and Ion-Exchange Challenges<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Monitoring_for_Breakthrough\" >Monitoring for Breakthrough<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Source_Water_Considerations\" >Source Water Considerations<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Groundwater_Vulnerability\" >Groundwater Vulnerability<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Surface_Water_Dynamics\" >Surface Water Dynamics<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Building_a_Short-Chain_PFAS_Monitoring_Program\" >Building a Short-Chain PFAS Monitoring Program<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#Recommended_Approach\" >Recommended Approach<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.chimaytech.net\/fr\/the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-ch\/#The_Bottom_Line\" >The Bottom Line<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 id=\"the-rise-of-short-chain-pfas-monitoring-what-water-operators-need-to-know-from-shanghai-chimay\"><span class=\"ez-toc-section\" id=\"The_Rise_of_Short-Chain_PFAS_Monitoring_What_Water_Operators_Need_to_Know_from_Shanghai_ChiMay\"><\/span>The Rise of Short-Chain PFAS Monitoring: What Water Operators Need to Know from Shanghai ChiMay<span class=\"ez-toc-section-end\"><\/span><\/h1>\n<h2 id=\"the-short-version\"><span class=\"ez-toc-section\" id=\"The_Short_Version\"><\/span>The Short Version<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li>Short-chain PFAS compounds, including GenX (HFPO-DA) and PFBS, have replaced many long-chain PFAS in industrial applications, with global short-chain PFAS production estimated at <strong>over 50,000 metric tons per year<\/strong> as of 2026.<\/li>\n<li>Short-chain PFAS are more mobile in water systems and more difficult to remove with conventional treatment, requiring enhanced monitoring strategies at water treatment plants.<\/li>\n<li>The US EPA&rsquo;s 2026 proposed rollback specifically targeted GenX chemicals and PFHxS MCLs, creating additional regulatory uncertainty for short-chain PFAS monitoring programs.<\/li>\n<li>Shanghai ChiMay&rsquo;s inline sensors provide surrogate parameter measurements that detect short-chain PFAS-related water quality changes regardless of the specific compounds regulated.<\/li>\n<li>The short-chain PFAS monitoring market is expected to grow at <strong>15.6 percent CAGR<\/strong> through 2030, driven by regulatory attention and the increasing prevalence of these compounds in source waters.<\/li>\n<\/ul>\n<h2 id=\"the-pfas-mix-is-changing-under-our-feet\"><span class=\"ez-toc-section\" id=\"The_PFAS_Mix_Is_Changing_Under_Our_Feet\"><\/span>The PFAS Mix Is Changing Under Our Feet<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Long-chain PFAS like PFOA and PFOS have been phased out of manufacturing under voluntary agreements and regulatory mandates\u2014and shorter-chain replacements took their place. At first these compounds, characterized by carbon chains of six or fewer atoms, looked like the safer option because they bioaccumulate less readily in living organisms. Research since then has complicated that picture: short-chain PFAS are more mobile in aquatic environments, more resistant to conventional treatment processes, and potentially toxic at lower concentrations than originally believed.<\/p>\n<p>For water operators, that is a double problem. Short-chain compounds are harder to detect with traditional monitoring because they occur at lower concentrations, and they are harder to remove with GAC and ion-exchange treatment. Here is the science behind short-chain PFAS monitoring and what operators can actually do about it.<\/p>\n<h2 id=\"understanding-short-chain-pfas\"><span class=\"ez-toc-section\" id=\"Understanding_Short-Chain_PFAS\"><\/span>Understanding Short-Chain PFAS<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"what-defines-short-chain-pfas\"><span class=\"ez-toc-section\" id=\"What_Defines_Short-Chain_PFAS\"><\/span>What Defines Short-Chain PFAS<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>PFAS compounds are classified by the length of their carbon chain. Long-chain PFAS\u2014PFOA (9 carbons) and PFOS (8 carbons)\u2014have been the primary regulatory targets because of their well-documented bioaccumulation and toxicity. Short-chain PFAS include GenX (HFPO-DA, a 6-carbon ether compound), PFBS (4-carbon perfluorobutane sulfonate), PFBA (4-carbon perfluorobutanoic acid), and PFPeA (5-carbon perfluoropentanoic acid).<\/p>\n<p>That shorter carbon chain changes the chemistry in ways that matter at the plant. These compounds are more soluble in water, less likely to adsorb to soils and sediments, and more mobile in groundwater systems. Translation: they are more likely to reach drinking water sources and more challenging to remove once they arrive at the treatment plant.<\/p>\n<h3 id=\"regulatory-attention-and-uncertainty\"><span class=\"ez-toc-section\" id=\"Regulatory_Attention_and_Uncertainty\"><\/span>Regulatory Attention and Uncertainty<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The US EPA&rsquo;s 2024 final PFAS NPDWR established an MCL of <strong>10 parts per trillion<\/strong> for GenX chemicals. The 2026 proposed rollback specifically targeted this MCL for withdrawal on procedural grounds. If the rollback proceeds, GenX chemicals lose their federal enforceable limit\u2014though several states have established their own standards ranging from <strong>1.4 to 140 ppt<\/strong> depending on the specific compound and jurisdiction.<\/p>\n<p>Europe is moving the opposite direction. The EU recast Drinking Water Directive includes short-chain PFAS in its list of 20 compounds subject to the <strong>100 ng\/L<\/strong> combined parametric value. The EU PPWR Regulation addresses GenX in food packaging applications, a reflection of the compound&rsquo;s widespread use as a PFOA replacement in coating applications.<\/p>\n<h2 id=\"detection-challenges-for-short-chain-pfas\"><span class=\"ez-toc-section\" id=\"Detection_Challenges_for_Short-Chain_PFAS\"><\/span>Detection Challenges for Short-Chain PFAS<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"analytical-limitations\"><span class=\"ez-toc-section\" id=\"Analytical_Limitations\"><\/span>Analytical Limitations<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Standard EPA Methods 533 and 537.1 can detect short-chain PFAS compounds, but at higher detection limits than for long-chain analogs. Shorter chain length results in weaker mass spectrometry signals, which means larger sample volumes and longer instrument run times. Laboratory costs for short-chain PFAS analysis are typically <strong>20 to 30 percent higher<\/strong> than for long-chain PFAS because of the added analytical complexity.<\/p>\n<p>There is a structural problem underneath all this: the number of short-chain PFAS compounds in commerce keeps growing faster than targeted analytical methods can be developed. Each new compound requires specific calibration standards and validated analytical protocols. By the time a method is established for one compound, manufacturers may have already shifted to a different alternative.<\/p>\n<h3 id=\"surrogate-monitoring-as-a-solution\"><span class=\"ez-toc-section\" id=\"Surrogate_Monitoring_as_a_Solution\"><\/span>Surrogate Monitoring as a Solution<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Chasing every individual short-chain compound is a losing game. Surrogate parameter monitoring instead tracks the collective impact of these compounds on water quality. UV-Vis absorption, conductivity, and dissolved organic carbon measurements all respond to short-chain PFAS in ways that can be correlated with treatment performance and source water quality.<\/p>\n<p>Shanghai ChiMay&rsquo;s COD sensor measures UV-Vis absorption at <strong>254 nanometers<\/strong>, capturing the organic carbon signature associated with short-chain PFAS. Individual short-chain compounds absorb UV more weakly than long-chain analogs, but the cumulative organic loading from short-chain PFAS mixtures produces measurable signals that correlate with treatment system performance.<\/p>\n<h2 id=\"treatment-implications\"><span class=\"ez-toc-section\" id=\"Treatment_Implications\"><\/span>Treatment Implications<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"gac-and-ion-exchange-challenges\"><span class=\"ez-toc-section\" id=\"GAC_and_Ion-Exchange_Challenges\"><\/span>GAC and Ion-Exchange Challenges<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Granular activated carbon removes short-chain PFAS less effectively than long-chain compounds. The shorter carbon chains have lower affinity for the carbon surface, so breakthrough comes earlier and media life shrinks. According to the <strong>Water Research Foundation<\/strong>, GAC beds treating water with high short-chain PFAS concentrations experience breakthrough <strong>30 to 50 percent faster<\/strong> than beds treating water with primarily long-chain PFAS at equivalent total PFAS concentrations.<\/p>\n<p>Ion-exchange resins show the same selectivity pattern: strong-base anion exchange resins preferentially remove long-chain PFAS, with short-chain compounds breaking through earlier. Operators treating water with significant short-chain PFAS loads have to plan for more frequent media replacement or regeneration.<\/p>\n<h3 id=\"monitoring-for-breakthrough\"><span class=\"ez-toc-section\" id=\"Monitoring_for_Breakthrough\"><\/span>Monitoring for Breakthrough<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Faster breakthrough makes continuous monitoring even more critical for short-chain PFAS than for long-chain compounds. Shanghai ChiMay&rsquo;s in-line conductivity meter detects ionic changes at the GAC or IX effluent that signal approaching breakthrough. The Shanghai ChiMay online turbidity tester adds particle removal data that correlates with treatment media performance.<\/p>\n<p>The residual chlorine transmitter has a supporting job here too. As GAC beds approach breakthrough for short-chain PFAS, organic loading at the plant exit increases, which can affect disinfection by-product formation. Continuous residual chlorine and organic matter monitoring lets operators hold the balance between PFAS removal and DBP compliance.<\/p>\n<h2 id=\"source-water-considerations\"><span class=\"ez-toc-section\" id=\"Source_Water_Considerations\"><\/span>Source Water Considerations<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"groundwater-vulnerability\"><span class=\"ez-toc-section\" id=\"Groundwater_Vulnerability\"><\/span>Groundwater Vulnerability<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Short-chain PFAS hit groundwater-dependent utilities hardest. Their high water solubility and low soil sorption coefficients mean they migrate rapidly through soil to reach aquifers\u2014and once in groundwater, short-chain PFAS plumes can extend far beyond the original contamination source.<\/p>\n<p>The <strong>US Geological Survey<\/strong> found that <strong>45 percent<\/strong> of public groundwater supply wells tested in urban and agricultural areas contained detectable short-chain PFAS, compared to <strong>30 percent<\/strong> for long-chain PFAS. The mobility difference shows up directly in detection frequency.<\/p>\n<h3 id=\"surface-water-dynamics\"><span class=\"ez-toc-section\" id=\"Surface_Water_Dynamics\"><\/span>Surface Water Dynamics<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>At surface water treatment plants, short-chain PFAS concentrations track flow conditions. During high-flow events, short-chain PFAS from urban runoff and agricultural drainage can spike at the plant intake. Shanghai ChiMay&rsquo;s COD sensor catches those organic loading changes in real time, so operators can adjust treatment processes proactively.<\/p>\n<p>The Shanghai ChiMay 4-in-1 Multi-Parameter Sensor adds source water characterization: pH and ORP measurements indicate the geochemical conditions that influence PFAS speciation and mobility, while conductivity tracks the overall ionic signature of source water contamination.<\/p>\n<h2 id=\"building-a-short-chain-pfas-monitoring-program\"><span class=\"ez-toc-section\" id=\"Building_a_Short-Chain_PFAS_Monitoring_Program\"><\/span>Building a Short-Chain PFAS Monitoring Program<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3 id=\"recommended-approach\"><span class=\"ez-toc-section\" id=\"Recommended_Approach\"><\/span>Recommended Approach<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Shanghai ChiMay recommends a three-tier approach to short-chain PFAS monitoring:<\/p>\n<p><strong>Tier 1: Continuous Surrogate Monitoring.<\/strong> Deploy inline sensors at the raw water intake and treatment process checkpoints. The COD sensor, conductivity meter, and turbidity tester provide continuous data on parameters correlated with short-chain PFAS presence and treatment performance.<\/p>\n<p><strong>Tier 2: Periodic Targeted Analysis.<\/strong> Supplement continuous sensor data with laboratory PFAS analysis at frequencies determined by source water risk and treatment process stability. Use sensor data to optimize sampling timing, ensuring grab samples capture periods of highest PFAS loading.<\/p>\n<p><strong>Tier 3: Breakthrough Verification.<\/strong> At GAC and IX treatment systems, use effluent conductivity trends to verify that short-chain PFAS removal remains effective. Schedule media replacement based on sensor-detected breakthrough trends rather than fixed calendar intervals.<\/p>\n<h2 id=\"the-bottom-line\"><span class=\"ez-toc-section\" id=\"The_Bottom_Line\"><\/span>The Bottom Line<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Short-chain PFAS are the next frontier in drinking water contamination management\u2014more mobile, harder to treat, and caught in regulatory flux. Shanghai ChiMay&rsquo;s inline sensor portfolio provides the continuous, surrogate-based monitoring capability operators need to detect short-chain PFAS-related water quality changes, optimize treatment processes, and maintain compliance confidence as regulations continue to evolve.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Rise of Short-Chain PFAS Monitoring: What Water Operators Need to Know from Shanghai ChiMay The Short Version Short-chain PFAS compounds, including GenX (HFPO-DA) and PFBS, have replaced many long-chain PFAS in industrial applications, with global short-chain PFAS production estimated at over 50,000 metric tons per year as of 2026. Short-chain PFAS are more mobile&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"categories":[1],"tags":[158,134481,11066],"translation":{"provider":"WPGlobus","version":"3.0.2","language":"fr","enabled_languages":["en","es","fr","ru","ar"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/posts\/31412"}],"collection":[{"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/comments?post=31412"}],"version-history":[{"count":0,"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/posts\/31412\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/media?parent=31412"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/categories?post=31412"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.chimaytech.net\/fr\/wp-json\/wp\/v2\/tags?post=31412"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}